Daily (every shift)
- Grease the chisel bushing every 2 hours, with the breaker standing on the chisel so grease reaches the gap.
- Check hoses and fittings for leaks and chafing.
- Check through bolts, side bolts and bracket bolts for looseness.
- Inspect the chisel for cracks and mushrooming.
Weekly
- Check the nitrogen (back-head) pressure with the charging kit.
- Measure clearance between chisel and lower bushing; replace when it exceeds the limit in the manual.
- Check retaining pins and stopper pins.
Hydraulic oil and filters
Breaker work heats and contaminates oil faster than digging. Use a return filter, keep oil temperature within the machine’s limits and change oil and filters more frequently than for bucket-only work.
Every 600–1,000 hours or annually
- Replace the seal kit and inspect piston and cylinder for scoring.
- Replace accumulator diaphragm (if fitted).
- Re-torque through bolts to the specified value.
Five mistakes that kill breakers
- Blank firing – running the hammer without the chisel on the material.
- Using the breaker to pry or lift.
- Breaking continuously for more than 30 seconds in one spot.
- Running under water without an air-supply kit.
- Skipping grease.
Storage
Store the breaker vertically, chisel removed and greased, nitrogen released, hose ends capped. We supply a printed manual and seal kits for every model; spare parts ship from stock.